BME Series
Air Shut Off Valves
- Solenoid Powered to Close/Manual Reset Butterfly Valve
- Part of the B Series of easily installed, compact, air intake valves for diesel engine emergency shut down
The Fluid Power Energy (FPE) BME valve series is designed to provide an emergency means for rapid shut down of a diesel engine, when triggered by a 12 or 24 volt signal. This signal may be generated automatically by an engine overspeed or any other selected fault conditions. It can also be generated by a manually operated electrical engine stop button. For additional safety, the valve can also be supplied with a mechanical emergency engine stop button. This can be either directly mounted on the valve or remotely mounted for use, via a mechanical cable.
Once the BME valve has worked to stop the engine, a restart is only possible after manually resetting the valve to the run position.
The low intake air flow restriction through the open valve, makes it generally compatible with the requirements of low emission diesel engines.
Corrosion resistant materials are used, where applicable, in the construction of the valve. This lightweight and compact valve design, together with the availability of factory fitted hose adapters selected from a wide range of optional sizes, assists in easy installation.
The valve may be fitted to either turbocharged or naturally aspirated engines. In the case of turbocharged engines, temperature limitations may restrict the position in which the valve is installed in the intake system.
Note: FPE also supplies speed switches for incorporation into the emergency shut down control circuit of this type of application. Please contact FPE or your FPE supplier for details.
Helpful Links
Description
The BME butterfly valve is a latched, open type, valve. Valve closure (engine stop) is done via a manual engine shut down button (when fitted), or applying a 12 volt or 24 volt signal. Following valve closure, the manual reset lever on the valve is used to reset to the latche dopen position. Optionally, the valve can be supplied with a cable and lever arrangement. This is to permit manual reset from a position remote from the engine.
In standard form, the BME valve is available compolete with formed hose adapters. These adapters are selected by the customer from a range of standard sizes (see page 5 & 6). If there is a requirement for a non-standard adapter size or other alternative form of pipe connection, such as a bolted joint, please share the requirements to FPE or your FPE supplier for investigation.
The valve is supplied fitted, as standard, with an internal microswitch to indicate the open/closed status of the valve.
The valve has a metal to metal seal when closed. It is designed for low friction while closing to ensure the sealing surfaces last a lifetime. The latch/release mechanism is configured to withstand high shock loads without malfunction. The electrical closure is designed to IP66 code.
The diagram on the following page and the information on pages 4-7 cover the main features and basic dimensions of the BME valve, including selection of options and order codes.
Dimensions
BME Series - Imperial Table
IMPERIAL TABLE | DIMENSIONS (INCHES) | WEIGHT (LB) | ORDER CODE | |||||
MODEL | H TO SUIT HOSE BORE | BORE A | B | C | D | E | ||
BME | 1.50 | 2.2 | 3.18 | 5.33 | 1.97 | 0.79 | 2.38 | 038 |
1.73 | 2.38 | 044 | ||||||
2.01 | 2.38 | 051 | ||||||
2.24 | 2.36 | 057 | ||||||
2.52 | 2.80 | 3.90 | 6.06 | 1.10 | 0.98 | 2.38 | 064 | |
2.76 | 2.45 | 070 | ||||||
2.99 | 2.32 | 076 | ||||||
3.27 | 2.51 | 083 | ||||||
3.50 | 3.74 | 4.92 | 7.09 | 1.38 | 0.98 | 2.67 | 089 | |
3.74 | 2.82 | 095 | ||||||
4.02 | 3.04 | 102 | ||||||
4.25 | 3.22 | 108 | ||||||
4.49 | 4.72 | 6.06 | 8.23 | 1.65 | 0.98 | 3.42 | 114 | |
4.76 | 3.66 | 121 | ||||||
5.00 | 4.06 | 127 | ||||||
5.24 | 4.30 | 133 | ||||||
5.51 | 5.71 | 7.28 | 9.49 | 1.93 | 0.98 | 4.56 | 140 | |
5.75 | 4.83 | 146 | ||||||
5.98 | 5.82 | 152 | ||||||
6.26 | 6.15 | 159 | ||||||
6.50 | 6.44 | 165 | ||||||
6.73 | 6.73 | 171 | ||||||
7.01 | 7.10 | 178 |
BME Series - Metric Table
METRIC TABLE | DIMENSIONS (MM) | WEIGHT (KG) | ORDER CODE | |||||
MODEL | H TO SUIT HOSE BORE | BORE A | B | C | D | E | ||
BME | 38 | 57 | 81w | 136 | 50 | 20 | 1.08 | 038 |
44 | 1.08 | 044 | ||||||
51 | 1.08 | 051 | ||||||
57 | 1.07 | 057 | ||||||
64 | 71 | 99 | 154 | 28 | 25 | 1.08 | 064 | |
70 | 1.11 | 070 | ||||||
76 | 1.05 | 076 | ||||||
83 | 1.14 | 083 | ||||||
89 | 95 | 125 | 180 | 35 | 25 | 1.21 | 089 | |
95 | 1.28 | 095 | ||||||
102 | 1.38 | 102 | ||||||
108 | 1.46 | 108 | ||||||
114 | 120 | 154 | 209 | 42 | 25 | 1.55 | 114 | |
121 | 1.66 | 121 | ||||||
127 | 1.84 | 127 | ||||||
133 | 1.95 | 133 | ||||||
140 | 145 | 185 | 241 | 49 | 25 | 2.07 | 140 | |
145 | 2.19 | 146 | ||||||
152 | 2.64 | 152 | ||||||
159 | 2.79 | 159 | ||||||
165 | 2.92 | 165 | ||||||
171 | 3.05 | 171 | ||||||
178 | 3.22 | 178 |
Part Number Look Up
FPE Number | Range in MM | AMOT/Chalwyn Number |
CO18- | 025 to 045 | D30 |
CFO20-* | 035 to 044 | D35BF |
CO27- | 035 to 044 | D41 |
CO45- | 045 to 070 | D45/D51** |
CO78- | 051 to 077 | D57/D64** |
CO90- | 070 to 089 | D70 |
C110- | 070 to 089 | D80 |
C140- | 089 to 102 | D92 |
C185- | 089 to 114 | D102 |
C235- | 102 to 140 | D121 |
C290- | 127 to 153 | D136 |
C450 | 152 to 229 | D200 |
* This ASV Includes a Filter
** FPE part numbers listed are used to replace both Amot/Chalwyn part numbers show
General & Pneumatic Specifications
BME Series - General and Electrical Specifications
GENERAL DESCRIPTION: | |
A slim butterfly valve designed for emergency shutoff of the engine air intake. | |
Mechanically latched open, energize to close, manual reset by rotation of reset knob. | |
GENERAL SPECIFICATION: | |
Temperature: | Max ambient: 248°F (120°C); Max intake air temp: 248°F (120°C) |
Construction: | Body and disk: Hard adonized aluminum; Other main components: Stainless steel, aluminum; Hose adaptors: Aluminum |
ELECTRICAL SPECIFICATION: | |
Solenoid energize to close operation | |
12 or 24 volt option specified when ordering | |
Solenoid rating: | 12 Volt, 7.5A, 90W; 24 Volt, 3.75A, 90W; Solenoid rating 10% |
Max single pulse @ 68°F (20°C): | 8 seconds |
Max on time in 1 minute @ 68°F (20°C): | 6 seconds |
Recommended engine controller setting: | 1 second |
MICROSWITCH: | |
S.P.S.T. - 24V, 10A Max | |
Code M1: Switch open when valve in open position | |
Code M2: Switch closed when valve in open position | |
CABLE: | |
SIHF silicone insulated multicore cable: Standard length 3m |
Valve Selection
The following data is required for FPE to select the most suitable valve for your application:
• Bore size of the intake hose into which the valve is to be fitted- refer to section headed “Mechanical Installation.”
• Where a 12 or 24 volt shut down signal is to be used
• For the microswitch operating mode – see “Valve Schematics” on page 7.
• For any option that requires cable – refer to the “Standard Cable Length” table below.
BME Series - Valve Selection
BME SERIES - FPE Coding | ||
Special features by arrangement with FPE | ||
BME | Butterfly style valve | |
12/24 | Voltage, 12 or 24 | |
XX | Adapter size (MM) | |
- | ||
MX | Microswitch Position- choose one; 1- Open when valve open; 2- Closed when valve open | |
- | ||
R | Manual Close Handle Style (T=T-Handle; L=Lever) | OPTIONAL |
- | ||
XX | Manual Shutdown Cable Length (Meters) | |
- | ||
XXX | Manual Stop Option; E (on -unit E-Stop); EXX remote E-Stop (specify cable length (Meters)) | |
- | ||
SOO | Special Features Code |